D015M - PC/30 MVB Interface / MVB Card

MVB-PC/30 Interface

Features

  • EMD / ESD+
  • MVB Bus Administrator
  • 4096 PD ports
  • MD-Stack
  • Serial / Parallel Bus
  • PC/30, 40 x 85mm

The D015M is a multi-purpose MVB interface on a 40 x 85mm size footprint (PC/30).

All features of the MVB architecture are available:

  • Process Data and Message Data
  • Full-featured Bus Administrator
  • EMD or ESD+.

The D015M is available in two configurations:

  • MDFULL: Passive MVB interface with a full-featured Duagon MVB controller; Process Data and Message data on link layer level
  • SERVER: Active MVB interface including the Message Data Real Time Protocol stack.

The D015M is designed for the harsh traction environment and is fully compliant to the EN 50155 standard.

 Downloads

Supporting devices

D213 - PCI MVB Interface

D213 - PCI MVB Interface

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD
D221 - PCI Express Adapter Card

D221 - PCI Express Adapter Card

  • PCIe Interface
  • PC/104 Slot
  • PC/30 Slot
D412 - MVB Diagnostic System

D412 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports
D442 - MVB Diagnostic System

D442 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports

Further Products

D515 - LoRaWAN to Ethernet Gateway

  • Hardware prioritisation within the duagon own Ethernet controller
  • Proprietary high-performance UDP Stack (optimised for cyclic process data telegrams)
  • Robust wireless communication based on LoRa® technology modulation
  • Fully compliant to IEEE 802.3, EN 50155, EN 50121, IEC 61373 and LoRaWAN™ 1.0

DAXIO3410C - CAN Analog I/O Module

  • CAN 2.0
  • CANopen
  • J1939
  • 3x Analog Input

DIO101 - Sibas PN I/O

  • Programmable digital I/O module
  • SIL2

D114RS - RS485-Interface

  • The "UART Emulation" interface is allows serial communication with the need for a real time operating system
  • Cost optimized interface card
  • Reducing CPU power on the Host System
  • Fully compliant to EN 50128, EN 50129, EN 50155, EN 50121, IEC 61373 and IEC 61375

D217 - PMC MVB Interface

  • MVB EMD/ESD+
  • 4096 PD Ports
  • MD-Stack
  • MVB Bus Administrator

i201 - Digital Input / Output Module

  • 16 Digital Inputs
  • Frequency Measurement
  • High Current Inputs
  • Overvoltage and Reverse Polarity Safe

i211 - Analog Input / Output Module

  • 12 Analog Inputs
  • Voltage, resistive or current measurement inputs
  • 25Hz Sampling Rate
  • 24bit Analog Digital Conversion

LoRaWAN

  • Energy efficient and long range
  • Open global standard for secure
  • Provides seamless interoperability among smart Things without the need of complex local installation