i211 - Analog Input / Output Module

High Precision Analog Input / Output Module

Features

  • 12 Analog Inputs
  • Voltage, resistive or current measurement inputs
  • 25Hz Sampling Rate
  • 24bit Analog Digital Conversion
  • Low Pass Filters
  • On-Board Calculation Functions

The intelligent high precision analog interface has 12 analog inputs grouped into four galvanically isolated sections. Each group can be individually selected as voltage, resistive or current measurement inputs.

The on-board controller supports independent digital low-pass filters and other calculation functions, that can be customized by the application developers.

Configuring the i211 is done easily and time saving by using one of the five methods defined by IEC 61131.

The i211 is designed for harsh rolling stock environments and is fully compliant to EN 50155.

Use ouronline configuratorto easily define your own TCMS system.

 Downloads

Supporting devices

ionia

ionia

  • Height: 100mm
  • Depth: 120mm
  • MVB
  • Ethernet
i201 - Digital Input / Output Module

i201 - Digital Input / Output Module

  • 16 Digital Inputs
  • Frequency Measurement
  • High Current Inputs
  • Overvoltage and Reverse Polarity Safe
i202 - Digital Input / Output Module

i202 - Digital Input / Output Module

  • 8 Digital HCI Inputs
  • 8 Digital Outputs
  • Frequency Measurement
  • PWM
i101 - MVB CPU Module

i101 - MVB CPU Module

  • MVB Consist Network
  • 32bit ARM CPU @ 720MHz
  • 1 GB Flash File System
  • 256MB DDR2-RAM
i012 - Compliant Power Module

i012 - Compliant Power Module

  • 20 Watt Output Power
  • 24 - 110Vdc
  • Reverse Polarity Safe
  • Overvoltage Protection
i303 - Dual / Single Ethernet Interface Module

i303 - Dual / Single Ethernet Interface Module

  • 2 Ethernet Interfaces
  • TCP/IP, UDP
  • IPTCom / TRDP
  • CIP, PROFINET
i306 - WTB Module

i306 - WTB Module

  • IEC 61375 Compliant
  • Fritting 48V
  • Strong and Weak Master
  • Slave

Further Products

D521 - WTB to MVB Gateway

  • Fritting without additional DC/DC converters
  • Configurable strong master, weak master and slave node
  • Cable redundancy Line A and Line B
  • Comparably small form factor

D523 - WTB to CAN Gateway

  • Dual MAU & Fritting
  • CAN Interface
  • IEC 61131
  • 24 - 110Vdc

DAXIO3410E - Ethernet Analog I/O Module

  • TCP/IP, UDP
  • IPTCom / TRDP
  • CIP, PROFINET
  • Webserver

DXIO0808C - CAN Digital I/O Module

  • CAN 2.0
  • CANopen
  • J1939
  • 8x Digital In-/Output

D016E - PCIe Ethernet Interface

  • TCP/IP, UDP
  • IPTCom/TRDP
  • CIP, PROFINET
  • PC/30+, 40 x 85mm

D017M - PCIe MVB Minicard

  • MVB Interface
  • EMD/ESD+
  • Process Data-Stack
  • Message Data-RT-Stack

D113 - PC/104 MVB Interface / MVB Card

  • EMD/ESD+
  • 4096 PD Ports
  • MD-Stack
  • MVB Bus Administrator

D203 PC/30+ - PCIe Adapter

  • PCI-Express 2.0
  • PC/30+ Carrier

D501/D502 Development Kit

  • - Phoenix Contact Plug with cable for power supply
  • - USB to Serial (RS232)
  • - Service Interface Adapter Print
  • - Ethernet Cable M12 to RJ45