D213 - PCI MVB Interface

PCI-MVB Interface

Features

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD
  • MD-Stack
  • PCI
  • WinXP, Win7 32/64bit Drivers

The D213 board connects MVB Multifunction Vehicle Bus devices to any PC via the PCI Bus. Testing and measurements in the laboratory becomes easy this way.

On the D213 board, a complete active MVB interface D113 is integrated, and one additional duagon device can be connected via PC/104.

 Downloads

Supporting devices

D113 - PC/104 MVB Interface / MVB Card

D113 - PC/104 MVB Interface / MVB Card

  • EMD/ESD+
  • 4096 PD Ports
  • MD-Stack
  • MVB Bus Administrator
D114L - PC/104 MVB Interface / MVB Card

D114L - PC/104 MVB Interface / MVB Card

  • EMD / ESD+
  • PD 16 / MD
  • PC/104
  • Easy-to-use UART Emulation
D134E - PC/104 Ethernet Interface

D134E - PC/104 Ethernet Interface

  • TCP/IP, UDP
  • IPTCom/TRDP
  • CIP, PROFINET
  • Webserver
D134C - CAN PC/104 Interface

D134C - CAN PC/104 Interface

  • CAN 2.0
  • CANOpen
  • J1939
  • PC/104
D135EML - MVB/Ethernet PC/104 Interface

D135EML - MVB/Ethernet PC/104 Interface

  • TCP/IP, UDP
  • IPTCOM / TRDP
  • CIP, PROFINET
  • MVB EMD/ESD+
D135ECL - Ethernet / CAN PC/104 Interface

D135ECL - Ethernet / CAN PC/104 Interface

  • TCP/IP, UDP
  • IPTCom / TRDP
  • PROFINET, CIP
  • CAN 2.0
D412 - MVB Diagnostic System

D412 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports
D442 - MVB Diagnostic System

D442 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports

Further Products

D210 - MVB Repeater

  • EMD, ESD+, Mixed
  • Redundant
  • 24-110Vdc

D512 - Ethernet Repeater

  • Supports all Ethernet protocols
  • Full duplex
  • Very low latency
  • Full 100Mbit bandwidth

D515 - LoRaWAN to Ethernet Gateway

  • Hardware prioritisation within the duagon own Ethernet controller
  • Proprietary high-performance UDP Stack (optimised for cyclic process data telegrams)
  • Robust wireless communication based on LoRa® technology modulation
  • Fully compliant to IEEE 802.3, EN 50155, EN 50121, IEC 61373 and LoRaWAN™ 1.0

DXIO0808C - CAN Digital I/O Module

  • CAN 2.0
  • CANopen
  • J1939
  • 8x Digital In-/Output

D018 - Fieldbus interface card

  • Supports all train born field buses: MVB, Ethernet, CAN, RS485, …
  • Supports nowadays CPU host interfaces like USB, QSPI, PCIe, Ethernet
  • Ready for high performance applications like used in VCU

D134C - CAN PC/104 Interface

  • CAN 2.0
  • CANOpen
  • J1939
  • PC/104

D211 - MVB Repeater

  • EMD, ESD+, Mixed
  • Redundant
  • 24-110Vdc, 5Vdc
  • 3U / 160mm

i211 - Analog Input / Output Module

  • 12 Analog Inputs
  • Voltage, resistive or current measurement inputs
  • 25Hz Sampling Rate
  • 24bit Analog Digital Conversion

INTEROS

  • Interconnection to INTEROS
  • Supporting protocols and services such as DHCP, ARP,...
  • Compatible to INTEROS
  • Passed JR's communication test