D521 - WTB to MVB Gateway

WTB - MVB Gateway

Features

  • Fritting without additional DC/DC converters
  • Configurable strong master, weak master and slave node
  • Cable redundancy Line A and Line B
  • Comparably small form factor
  • Complies with EN 50155, EN 50121 and IEC 61375 standards, and is designed for harsh rolling stock environment

The D521 is a WTB to MVB Gateway compliant to IEC 61375 and UIC Leaflet 556. The gateway is built with two WTB medium attachment units. Line A and B interfaces are galvanically isolated, enabling cable redundancy, and use standard 9-pole SUB-D type connectors. To overcome contact oxidation, the WTB gateway has an optional built-in fritting mechanism. The integrated WTB controller, realized on FPGA with duagon IP, can be configured to act as a strong or weak master or as a slave.

The gateway is delivered with a build-in UIC 556 conform mapping server application, handling message data communication and process data marshalling between the WTB and the MVB consist network. Safe data transmission can optionally be ordered. A complete configuration and integration toolchain is provided, including a configuration tool, to easily configure the application and allowing the gateway to be seamlessly inte-grated into any network architecture.

duagon's own MVB controller is implemented on FPGA and supports the full 4096 process data ports. The train consist network interface complies with the TCN standard IEC 61375 up to class 4. The D521 offers 8 digital inputs and 8 combined input/output channels. The I/O channels are used by the application to implement battery voltage monitoring, redundancy switch over and a "wake-up" signal. The WTB gateway is connected directly to the train battery and supports all voltage types from 24 to 110 Vdc. Moreover, it has a built-in power save mode. The service interfaces accessible via Ethernet offers quick access to diagnostic information and all recorded data.

The D521 is designed for harsh rolling stock environments and is fully compliant with EN 50155.

 

 Downloads

Supporting devices

D213 - PCI MVB Interface

D213 - PCI MVB Interface

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD
D412 - MVB Diagnostic System

D412 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports
D442 - MVB Diagnostic System

D442 - MVB Diagnostic System

  • EMD / ESD+
  • MVB Monitor
  • MVB Bus Administrator
  • 4096 PD Ports

Further Products

D222R - Redundant MVB Medium Converter

  • MVB EMD/ESD+
  • 2x OGF Lines
  • 24-110V
  • DIN Rail Mount

D503 - MVB to Ethernet Gateway

  • TCP/IP, UDP
  • IPTCOM / TRDP
  • CIP, PROFINET
  • MVB EMD / ESD+

D512 - Ethernet Repeater

  • Supports all Ethernet protocols
  • Full duplex
  • Very low latency
  • Full 100Mbit bandwidth

D515 - LoRaWAN to Ethernet Gateway

  • Hardware prioritisation within the duagon own Ethernet controller
  • Proprietary high-performance UDP Stack (optimised for cyclic process data telegrams)
  • Robust wireless communication based on LoRa® technology modulation
  • Fully compliant to IEEE 802.3, EN 50155, EN 50121, IEC 61373 and LoRaWAN™ 1.0

D015C - PC/30 CAN Interface

  • CAN 2.0
  • CANopen
  • PC/30, 40 x 85 mm
  • Serial / Parallel Bus

D018 - Fieldbus interface card

  • Supports all train born field buses: MVB, Ethernet, CAN, RS485, …
  • Supports nowadays CPU host interfaces like USB, QSPI, PCIe, Ethernet
  • Ready for high performance applications like used in VCU

D217 - PMC MVB Interface

  • MVB EMD/ESD+
  • 4096 PD Ports
  • MD-Stack
  • MVB Bus Administrator

i306 - WTB Module

  • IEC 61375 Compliant
  • Fritting 48V
  • Strong and Weak Master
  • Slave

LON

  • International norm acknowledged by IEC and ISO
  • Standard network variable types to allow communication between nodes from different producers